Department of Atomic Energy
Nuclear Power Plants
Posted On:
11 MAR 2020 2:21PM by PIB Delhi
The details of projects under construction and new projects accorded sanction are as follows:
Project
|
Location & State
|
Type
|
Capacity
(MW)
|
Sanctioned Cost
(Rs. crore)
|
Projects under Construction
|
KAPP 3&4
|
Kakrapar, Gujarat
|
PHWR
|
2 X 700
|
11459#
|
RAPP 7&8
|
Rawatbhata, Rajasthan
|
2 X 700
|
12320*
|
GHAVP 1&2
|
Gorakhpur, Haryana
|
2 X 700
|
20594
|
KKNPP 3&4
|
Kudankulam, Tamil Nadu
|
LWR
|
2 X 1000
|
39849
|
PFBR
|
Kalpakkam, Tamil Nadu
|
FBR
|
1 X 500
|
5677
|
New Projects accorded Administrative approval & financial sanction
|
KKNPP 5&6
|
Kudankulam, Tamil Nadu
|
LWR
|
2 X 1000
|
49621
|
Chutka-1&2
|
Chutka, Madhya Pradesh
|
PHWR
|
2 X 700
|
105000
|
Kaiga-5&6
|
Kaiga, Karnataka
|
2 X 700
|
MahiBanswara- 1&2
|
MahiBanswara, Rajasthan
|
2 X 700
|
GHAVP– 3&4
|
Gorakhpur, Haryana
|
2 X 700
|
MahiBanswara- 3&4
|
MahiBanswara, Rajasthan
|
2 X 700
|
|
|
|
|
|
|
‘#’ under revision to Rs 16580 crore ‘*’under revision to Rs. 17079 crore
PHWR – Pressurised Heavy Water Reactor LWR – Light Water Reactor FBR – Fast Breeder Reactor
The Pressurised Heavy Water Reactors (PHWRs) are fuelled by Natural Uranium while Light Water Reactors (LWRs) are fuelled by Low Enriched Uranium. The annual requirement of fuel (UO2) of a 700 MW PHWR (at 85% Capacity Factor) is about 125 tons and that of a 1000 MW LWR (at a capacity factor of 90%), about 25 tons. Prototype Fast Breeder Reactor (PFBR) being implemented by Bharatiya Nabhikiya Vidyut Nigam Limited (BHAVINI) is fuelled by Mixed Oxide (MoX) Fuel.
The installed power generation capacity, utilisation and production cost per unit of each of the nuclear power plants in the country, nuclear plant-wise;
Unit
|
State
|
Location
|
Capacity
(MW)
|
Capacity
Utilisation(PLF),
2019-20
(uptoJan 20)
|
Electricity Tariff
(Paise/ kWh)
|
TAPS-1
|
Maharashtra
|
Tarapur
|
160
|
81.15
|
206.24
|
TAPS-2
|
160
|
90.91
|
TAPS-3
|
540
|
76.62
|
307.64
|
TAPS-4
|
540
|
94.86
|
RAPS-1*
|
Rajasthan
|
Rawatbhata
|
100
|
-
|
--
|
RAPS-2
|
200
|
77.54
|
349.06
|
RAPS-3
|
220
|
88.98
|
RAPS-4
|
220
|
98.41
|
RAPS-5
|
220
|
99.88
|
406.28
|
RAPS-6
|
220
|
95.07
|
NAPS-1
|
Uttar Pradesh
|
Narora
|
220
|
98.03
|
320.32
|
NAPS-2
|
220
|
97.51
|
KAPS-1
|
Gujarat
|
Kakrapar
|
220
|
86.36
|
249.06
|
KAPS-2
|
220
|
101.52
|
KGS-1
|
Karnataka
|
Kaiga
|
220
|
94.01
|
364.84
|
KGS-2
|
220
|
91.58
|
KGS-3
|
220
|
93.85
|
KGS-4
|
220
|
98.50
|
MAPS-1#
|
Tamil Nadu
|
Kalpakkam
|
220
|
-
|
279.73
|
MAPS-2
|
220
|
94.13
|
KKNPP-1
|
Kudankulam
|
1000
|
80.15
|
412.06
|
KKNPP-2
|
1000
|
49.58
|
* RAPS-1 is under extended shutdown for techno-economic assessment for continued operation.
#MAPS-1 is in project mode for Endshield related works.
This information was provided by the Union Minister of State (Independent Charge) Development of North-Eastern Region (DoNER), MoS PMO, Personnel, Public Grievances & Pensions, Atomic Energy and Space, Dr Jitendra Singh in written reply to a question in Lok Sabha today.
****
VG/SNC/JM
(Release ID: 1605939)
Visitor Counter : 6785
Read this release in:
Urdu